# RTC Calibration

Calibrate the PCF85063A RTC crystal frequency on Soldered Inkplate 4 using LVGL.

## Overview

Initialises the PCF85063A RTC with default calibration settings and prints HH:MM:SS to the serial console every second. Adjust `setClockOffset()` to fine-tune the crystal frequency.

If the RTC drifts, adjust the offset value — negative values slow the clock, positive speed it up. Compare against a reference clock over several minutes.

## Hardware Required

- Soldered Inkplate 4
- USB cable

## Setup

Run `idf.py menuconfig` and navigate to:
**Inkplate Boards → Inkplate4**

## Build and Flash

```
idf.py build
idf.py -p PORT flash monitor
```

## Expected Output

- Display shows status prompts.
- Open serial monitor at 115200 baud.
- RTC starts at 00:00:00 and prints `HH:MM:SS` every second.
- Compare with a reference clock; adjust `setClockOffset()` as needed.

## Notes

- `setInternalCapacitor(true)` selects the 12.5 pF internal load capacitor.
- `setClockOffset(mode, value)`: mode 1 = correction every 4 minutes; value is two's complement offset (–63 to +63).